Standard for calibration of gas flow meters in hydrogen refuelling stations

Kjeller, Norja | Justervesenet
Julkaistu 2 kuukautta sitten | 26.5.2026 Alkuperäinen ilmoitus

Justervesenet needs a standard that will enable the calibration of gas flow meters in hydrogen refuelling stations (HRSs). The entire standard is termed HDFTS (Heavy-Duty Field Test Standard). It is a mobile standard that can be lifted onto a car trailer and driven to a HRS for testing. The standard consists of two parts: (1) a pair of Coriolis flow metres operating in parallel and (2) a tank system. Part 1 is termed CMU (Coriolis Measurement Unit) and 2 is HST (Hydrogen Storage Tanks). The operating pressure range must be at least from 0 to 900 barg and the rig must be designed to measure flow rates at least from 0.075 to 18 kg/min at ambient temperatures (15-25°C).

Ilmoitusnumero 358991-2026
Ilmoitusta kuvaavat CPV-Koodit Kaasusäiliöt (44612200), Putkiverkon asennustyöt (45231112), Putkijohdon uudelleenasennustyöt (45231113), Kaasun säätölaitteiden asennustyöt (45333100), Kaasumittarien asennustyöt (45333200), Kaasun varastointipalvelut (63121110), Maakaasu (09123000), Vety (24111600), Typpi (24111700), Metaani (24321111), Nesteiden tai kaasujen virtaus-, pinnankorkeus- ja painemittarit (38420000), Manometrit (38425100), Kaasunilmaisimet (38431100), Putkistot (44162000)
EUVL S 100/2026
Ilmoitustyyppi Ilmoitus tehdystä sopimuksesta